Photo of Opus 600 Master Control Unit - MCU610
Full product details
The MCU610 is the Master Control Unit for the Opus 6 Series, functioning as an audio and control distribution matrix. Up to 3 internal audio source modules can be fitted including FM/AM(standard), DAB+/FM(optional) and streaming audio (optional expected Q1, 2012).
Including 3 internal sources, the MCU610 can support a total 14 sources and distribute simultaneously to 6 main zones and 6 sub-zones. For larger installations MCU610s can be linked to serve up to 36 main zones and 36 sub-zones.
Comprehensive control options include IR, 232 and IP via Ethernet.
Features
6 main zone outputs - each main zone can support an additional sub-zone (6 sub-zones)
Two virtual zones (when used with VMX610)
Up to 6 MCU610s can be linked together (36 main zones)
5 x standard input connections
6 x zone by zone assignable inputs
3 x audio module expansion slots*
Includes FMM610 radio module
All off and party mode functions
3 x RS-232/422 connectors for integration with lighting,
HVAC, blind, video matrix and third party control products
Routed IR emitter outputs for dedicated control of source equipment
Full IR pass-through capability for control of source equipment via remote controls
Page and alarm inputs plus, mute input for integration with telephone system or doorbell etc
PC programming via direct USB cable into MCU610
Includes rack mount kit
Includes Lacing Bar for cable management
Wall mountable (optional kit available)
*For more information on audio modules, please see individual specification sheets. Any combination of audio can be used to achieve independent and simultaneous access in up to three zones.
Specifications
Input impedance: 100k
Frequency response: 20Hz - 20kHz +/- 1dB
THD: <0.006% 20Hz - 20kHz
S/N ratio: >86dB A weighted
Cross-talk / channel separation: >84dB A weighted
Com port 1: RS-232 or RS-422
Com port 2: RS-232 or RS-422
Com port 3: RS-232 or RS-422
RS-232 standard: EIA/TIA-232 on 9 pin D-connector (TIA457) at 9600N1 RTS/CTS can be enabled or disabled
RS-422 standard: Full duplex, balanced at 600N1, 100 Ohm RX termination
Mains voltage (switchable): 110 120V or 220 240 V AC @ 50-6-Hz
Standby power consumption (power saving mode:) 1 Watt
Weight: 17Kg
Dimensions (WxHxD): 430 x 152 x 378mm
CE marked to regulations:
EN60065:2002+A1/A11 (safety)
EN55022:2006+A1 (EMC)
EN55024:1998+A2 (EMC)
EN6100032:2006+A2 (EMC)
EN6100033:2008 (EMC)
EN62301:2005 (ErP)
Reviews - Opus 600 Master Control Unit - MCU610